Author/Authors :
Meschini، نويسنده , , M. and Albergo، نويسنده , , S. and Angarano، نويسنده , , M. and Azzi، نويسنده , , P. and Babucci، نويسنده , , E. and Bacchetta، نويسنده , , N. and Bader، نويسنده , , A. and Bagliesi، نويسنده , , G. and Basti، نويسنده , , A. and Biggeri، نويسنده , , U. and Bilei، نويسنده , , G.M and Bisello، نويسنده , , D. and Boemi، نويسنده , , D. and Bosi، نويسنده , , F. and Borrello، نويسنده , , L. and Bozzi، نويسنده , , C. and Braiban، نويسنده ,
Abstract :
We present results obtained with full-size wedge silicon microstrip detectors bonded to APV6 (Raymond et al., Proceedings of the 3rd Workshop on Electronics for LHC Experiments, CERN/LHCC/97-60) readout chips. We used two identical modules, each consisting of two crystals bonded together. One module was irradiated with 1.7×1014 neutrons/cm2. The detectors have been characterized both in the laboratory and by exposing them to a beam of minimum ionizing particles. The results obtained are a good starting point for the evaluation of the performance of the “ensemble” detector plus readout chip in a version very similar to the final production one. We detected the signal from minimum ionizing particles with a signal-to-noise ratio ranging from 9.3 for the irradiated detector up to 20.5 for the non-irradiated detector, provided the parameters of the readout chips are carefully tuned.