Abstract :
An ionizing detector for on-line registration and representation of the geometric SR beam parameters was developed in RRC KI. The detector analyses the products of the residual gas ionization, which was done by the investigated beam. Special electrostatic optics and open image converter tube (ICT) form optical image of the real beam on the screen of ICT. The detector was checked on SR beams of the next storage rings: DCI (LURE, Orsey, France), KSRS (RRC KI, Moscow, Russia) and MAX-2 (MAX-lab, Lund, Sweden). The codes for TV image processing give a possibility for numeric estimation of the beam size, the width of its horizontal and vertical profiles and position of the beam gravity. Statistic processing of the beam gravity center using big amount of TV frames gives uncertainty in the beam position of about 2 μm while the width of the beam is about 2 mm. Summation of big amount of TV frames was used. This method significantly increases signal-to-noise ratio.
Keywords :
Cross Section , IMAGE , Synchrotron radiation , Monitoring , Beam