Abstract :
The P ¯ ANDA experiment will make use of cooled antiproton beams of unprecedented quality that will become available at the Facility for Antiproton and Ion Research in Darmstadt, featuring a 1.5–15 GeV/c momentum range. The physics program includes measurements of hyperons produced at low energies, spectroscopy of charmonium and open-charm mesons. To handle the forward peaked particle distribution due to the Lorentz boost, the apparatus is arranged in an asymmetric layout around the interaction point. In particular the Micro Vertex Detector based on silicon devices will have a rather unusual geometry. The MVD features fast data readout, since the experiment is triggerless, particle identification over the full range of energies, limited material budget and good spatial and time resolution. The status of the MVD design is shown and the present prototypes are described.
Keywords :
Micro Vertex Detector , Antiproton annihilation , Hybrid pixel detector