Title of article :
ATLAS monitored drift tube chambers for super-LHC
Author/Authors :
Engl، نويسنده , , Albert and Biebel، نويسنده , , Otmar and Hertenberger، نويسنده , , Ralf and Mlynek، نويسنده , , Alexander and Mueller، نويسنده , , Thomas A. and Rauscher، نويسنده , , Felix، نويسنده ,
Pages :
3
From page :
91
To page :
93
Abstract :
After the high-luminosity upgrade of the Large Hadron Collider (LHC), the ATLAS muon spectrometer is expected to work at 10-fold background rates of gammas and neutrons. As the momentum resolution of the spectrometer is expected to be 10% a single tube resolution of the muon drift tubes of 80 μ m is required. At background rates around 1000 Hz/cm 2 space charge effects will lead in the slow and non-linear AR:CO2=93:7 gas mixture degrade the drift-tube spatial resolution. While this was studied for gammas and low energetic neutrons, almost no information exists for fast neutrons. aper shows that: • neutrons at flux densities of 4 and 16 kHz/cm2 degrade the position resolution by only 10 μ m at a detection efficiency of 4 × 10 −4. dified inert gas mixtures selected by fastness and linearity of their position-drifttime ( r–t) relation show similar resolution as the standard gas in agreement with Garfield simulations. solution of newly developed 15 mm ∅ drift tubes are mostly unaffected by space charge effects due to gamma irradiation up to 1400 Hz/cm2 according to Garfield simulations.
Keywords :
neutron background , 15  , Alternative drift gas mixtures , mm drift tube at ? irradiation
Journal title :
Astroparticle Physics
Record number :
2014904
Link To Document :
بازگشت