Author/Authors :
Yoneda، نويسنده , , Yasuhiro and Matsumoto، نويسنده , , Norimasa and Furukawa، نويسنده , , Yukito and Ishikawa، نويسنده , , Tetsuya، نويسنده ,
Abstract :
The performance of sagittal focusing for hard X-rays with a cylindrical bent crystal at SPring-8 is described. This bending mechanism is designed for the SPring-8 standard double crystal monochromator of bending-magnet beamlines. Therefore, a fixed height exit for a wide energy range (5 – 150 keV) is required. The results underline that focusing in a wide energy band was achieved by combining an adjustable inclined double crystal monochromator and a fixed height exit bending mechanism. The monochromator was maintained at a constant focus at the sample position by optimizing the bent crystal in the energy range from 60 to 150 keV.