Title of article :
Cosmic-ray tests of the Dط preshower detector
Author/Authors :
Baringer، نويسنده , , P and Bross، نويسنده , , A and Buescher، نويسنده , , V and Canelli، نويسنده , , F and Davis، نويسنده , , G and Del Signore، نويسنده , , K and Desai، نويسنده , , S and Estrada، نويسنده , , J and Ginther، نويسنده , , G and Gordeev، نويسنده , , A and Grannis، نويسنده , , A. and Grünendahl، نويسنده , , S and Hou، نويسنده , , S and Kotcher، نويسنده , , J and Lincoln، نويسنده , , D and Liu، نويسنده , , M and Mayorov، نويسنده , , A.A and Nea، نويسنده ,
Pages :
16
From page :
295
To page :
310
Abstract :
The Dط preshower detector consists of scintillator strips with embedded wavelength-shifting fibers, and a readout using Visible Light Photon Counters. The response to minimum ionizing particles has been tested with cosmic-ray muons. We report results on the gain calibration and light-yield distributions. The spatial resolution is investigated taking into account the light sharing between strips, the effects of multiple scattering and various systematic uncertainties. The detection efficiency and noise contamination are also investigated.
Journal title :
Astroparticle Physics
Record number :
2017071
Link To Document :
بازگشت