Author/Authors :
Katzir، نويسنده , , Y. and Ferber، نويسنده , , Y. and Megidish، نويسنده , , E. and Zigler، نويسنده , , A. and Milchberg، نويسنده , , H.M.، نويسنده ,
Abstract :
Quasi-phase matching third harmonic of Ti:sapphire laser was measured by propagation through corrugated discharge capillaries. The 1 cm long capillary with periodical varying inner radius was used with corrugation frequency of 200 μm. The longitudinal plasma density was periodically varied by a discharge current ablating the inner capillary walls, altering the refractive index accordingly. Average plasma density measured was 1018 cm−3 at minimum corrugation radius. Peak laser intensity was 1010 W/cm2 allowing enough pondermotive energy to the electron for high harmonic generation.
Keywords :
HHG , high harmonic generation , PLASMA , Quasi-phase matching , capillary