Author/Authors :
Amsler، نويسنده , , C and Bِsiger، نويسنده , , K and Glنttli، نويسنده , , M and Kaufmann، نويسنده , , R and Ould-Saada، نويسنده , , F and Regenfus، نويسنده , , C and Riedler، نويسنده , , P and Spanier، نويسنده , , S، نويسنده ,
Abstract :
We describe the design and present the performances of a charged particle telescope used for high resolution silicon pixel developments. A telescope made of four x and four y single-sided silicon microstrip layers was built, providing an r.m.s. position resolution of 1 μm for high energy charged particles. A signal over noise ratio of 130 was achieved with minimum ionizing particles.