Title of article :
The LHCb Silicon Inner Tracker
Author/Authors :
Sievers، نويسنده , , P.، نويسنده ,
Pages :
4
From page :
23
To page :
26
Abstract :
A silicon strip detector has been adopted as baseline technology for the LHCb Inner Tracker system. It consists of nine planar stations covering a cross-shaped area around the LHCb beam pipe. Depending on the final layout of the stations the sensitive surface of the Inner Tracker will be of the order of 14 m2. Ladders have to be 22 cm long and the pitch of the sensors should be as large as possible in order to reduce costs of the readout electronics. Major design criteria are material budget, short shaping time and a moderate spatial resolution of about 80 μm. After an introduction on the requirements of the LHCb Inner Tracker we present a description and characterization of silicon prototype sensors. First, laboratory and test beam results are discussed.
Keywords :
Silicon detector , LHCB , Tracking detector
Journal title :
Astroparticle Physics
Record number :
2019536
Link To Document :
بازگشت