Author/Authors :
Doll، نويسنده , , D and Fischer، نويسنده , , P and Hillert، نويسنده , , W and Krüger، نويسنده , , H and Stammschroer، نويسنده , , K and Wermes، نويسنده , , N، نويسنده ,
Abstract :
A detector for the detection of laser photons backscattered off an incident high-energy electron beam for precision Compton polarimetry in the 3.5 GeV electron stretcher ring ELSA at Bonn University has been developed using individual photon counting. The photon counting detector is based on a silicon microstrip detector system using dedicated ASIC chips. The produced hits by the pair converted Compton photons are accumulated rather than individually read out. A transverse profile displacement can be measured with μm accuracy rendering a polarization measurement of the order of 1% on the time scale of 10–15 min possible.
Keywords :
Microstrip detector , Polarimetry , Polarization , Compton scattering