Author/Authors :
Kuntner، نويسنده , , C and Auffray، نويسنده , , E and Lecoq، نويسنده , , P and Pizzolotto، نويسنده , , C and Schneegans، نويسنده , , M، نويسنده ,
Abstract :
Light output and energy resolution for a 2×2×10 mm3 LuYAP:Ce crystal coupled to a XP2020Q photomultiplier were studied. The measured light output of 8530 photons/MeV includes the correction for the quantum efficiency of the XP2020Q photomultiplier. An energy resolution of 7.33% was obtained for 662 keV γ-rays with a long face coupled to the PMT. The measured number of 2130 phe/MeV implies a photoelectron statistical contribution of 6.59% and hence a LuYAP intrinsic energy resolution of 3.21%. The relative light output of the LuYAP scintillator measured for photon energies varying from 31 keV to 1.333 MeV was constant within 7%. These observations are consistent with results for the YAP:Ce scintillator, and with the assumption that there is a direct correlation between the energy resolution of scintillators and non-proportionality of their light output versus energy in the low-energy domain. The results are compared to the relative light output of the LSO:Ce scintillator measured for varying energies.
Keywords :
Energy resolution , Scintillators , Light yield , Non-proportionality of light output , Lux(RE3+)1?xAP:Ce crystals