Title of article
Measurement of the refractive index of silica aerogel in vacuum
Author/Authors
Richter، نويسنده , , D and Lipka، نويسنده , , D، نويسنده ,
Pages
4
From page
635
To page
638
Abstract
The photo injector test facility at DESY Zeuthen (PITZ) uses Cherenkov radiation of electrons inside aerogel to measure the bunch length of an electron beam. To evaluate the results the refractive index of the aerogel has to be precisely known. The aerogel is used either at atmospheric pressure or in vacuum. The pressure dependence of the refractive index of two aerogel samples is investigated in the range between high vacuum (10−5 mbar) and atmospheric pressure.
Keywords
Vacuum , Refractive index , aerogel
Journal title
Astroparticle Physics
Record number
2021762