Author/Authors :
Carboni، نويسنده , , G. and De Capua، نويسنده , , S. and Domenici، نويسنده , , D. and Ganis، نويسنده , , G. and Messi، نويسنده , , R. and Passaleva، نويسنده , , G. and Santovetti، نويسنده , , E. P. Veltri، نويسنده , , M.، نويسنده ,
Abstract :
We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility, on two bakelite Resistive Plate Chambers (RPC) detectors. With a method based on a model describing the behavior of an RPC exposed to a large particle flux, we have periodically measured the electrode resistivity ρ of the two detectors over 3 years. We observed a large increase of ρ with time, from initial values of about 1010 Ω cm to more than 200×1010 Ω cm. A corresponding degradation of the RPC rate capability, from about 3 kHz/cm2 to less than 200 Hz/cm2, was observed. The reversibility of the process, using a humid gas mixture, has also been studied.
Keywords :
detector , RPC , Current , resistivity , Bakelite , Humid gas