Title of article :
A compact, continuous adiabatic demagnetization refrigerator with high heat sink temperature
Author/Authors :
Shirron، نويسنده , , P.J. and Canavan، نويسنده , , E.R. and DiPirro، نويسنده , , M.J and Jackson، نويسنده , , M. and Tuttle، نويسنده , , J.G.، نويسنده ,
Pages :
3
From page :
647
To page :
649
Abstract :
In the continuous adiabatic demagnetization refrigerator (ADR), the existence of a constant temperature stage attached to the load breaks the link between the requirements of the load (usually a detector array) and the operation of the ADR. This allows the ADR to be cycled much faster, which yields more than an order of magnitude improvement in cooling power density over single-shot ADRs. Recent effort has focused on developing compact, efficient higher temperature stages. An important part of this work has been the development of passive gas-gap heat switches that transition (from conductive to insulating) at temperatures around 1 and 4 K without the use of an actively heated getter. We have found that by carefully adjusting available surface area and the number of 3He monolayers, gas-gap switches can be made to operate passively. Passive operation greatly reduces switching time and eliminates an important parasitic heat load. The current four stage ADR provides 6 μW of cooling at 50 mK (21 μW at 100 mK) and weighs less than 8 kg. It operates from a 4.2 K heat sink, which can be provided by an unpumped He bath or many commercially available mechanical cryocoolers. Reduction in critical current with temperature in our fourth stage NbTi magnet presently limits the maximum temperature of our system to ∼5 K. We are developing compact, low-current Nb3Sn magnets that will raise the maximum heat sink temperature to over 10 K.
Keywords :
Magnetic refigeration , ADR
Journal title :
Astroparticle Physics
Record number :
2023035
Link To Document :
بازگشت