Title of article
The FastGas detector
Author/Authors
Bateman، نويسنده , , J.E. and Dalgliesh، نويسنده , , R.M. and Duxbury، نويسنده , , D.M. and Holt، نويسنده , , S.A. and McPhail، نويسنده , , D.J. and Marsh، نويسنده , , A.S. and Rhodes، نويسنده , , N.J and Schooneveld، نويسنده , , E.M. and Spill، نويسنده , , E.J. and Stephenson، نويسنده , , R.، نويسنده ,
Pages
6
From page
59
To page
64
Abstract
The development and testing of the FastGas neutron detector is described. Based on a Gas Microstrip Chamber the aim of the project was to produce a high counting rate detector capable of replacing the existing 3He tubes for specular reflectometry, currently in use on the ISIS reflectometer instruments. The detector system is described together with results of neutron beam tests carried out at the ISIS spallation neutron source.
Keywords
neutron detector , reflectometry , MSGC , Gas detector , 3He
Journal title
Astroparticle Physics
Record number
2023970
Link To Document