Title of article :
Study in a beam test of the resolution of a Micromegas TPC with standard readout pads
Author/Authors :
S. and Arogancia، نويسنده , , D.C. and Bacala، نويسنده , , A.M. and Boudjemline، نويسنده , , K. and Burke، نويسنده , , D.R. and Colas، نويسنده , , P. and Dixit، نويسنده , , M. and Fujii، نويسنده , , K. and Fujishima، نويسنده , , H. and Giganon، نويسنده , , A. and Giomataris، نويسنده , , I. and Gooc، نويسنده , , H.C. and Habu، نويسنده , , M. and Higashi، نويسنده , , T. and Kato، نويسنده , , Y. and Kobayashi، نويسنده , , M. and Kuroiwa، نويسنده , , H. ، نويسنده ,
Pages :
12
From page :
403
To page :
414
Abstract :
The results of a beam test performed at the KEK PS in June 2005 are presented. Drift properties of an argon–isobutane mixture have been accurately measured and compared with predictions at magnetic fields between 0 and 1 T. The r.m.s. point resolution of a padrow is compared with simulation and with an analytical calculation. The fundamental limitations due to detector geometry and gas properties are reviewed and the measured performances of the detector are found to be close to this limit. A numerical application to the case of a linear collider Time Projection Chamber (TPC) is presented.
Keywords :
Micromegas , Spatial resolution , Time projection chamber , iLC
Journal title :
Astroparticle Physics
Record number :
2025074
Link To Document :
بازگشت