Title of article
ATLAS RPC certification with cosmic rays
Author/Authors
Bianco، نويسنده , , M. and Chiodini، نويسنده , , G. and Gorini، نويسنده , , E. and Grancagnolo، نويسنده , , F. and Perrino، نويسنده , , R. and Primavera، نويسنده , , M. and Spagnolo، نويسنده , , S.، نويسنده ,
Pages
5
From page
700
To page
704
Abstract
Almost one-third of the 1116 resistive plate chamber (RPC) units installed in the ATLAS experiment was tested and certified at the Lecce Cosmic Ray Testing Facility. About half of these units belong to the same chamber typology named barrel outer small (BOS).
arge and nearly homogeneous sample allowed to perform an extensive study of the detector behavior and characteristics. The intrinsic spread of the chamber parameters was extracted after correction for known pressure and temperature effects. A residual dependence on pressure and temperature has been found and empirically corrected.
stribution of gas gap and panel efficiencies, cluster sizes (CSs), single rates and dark currents versus the applied threshold and high voltage was measured. An optimal working point was defined for each gas volume and the distribution of all relevant parameters was studied at the average working point for different voltage threshold. This work shows that the single unit BOS ATLAS RPC meets the experiment requirements.
Keywords
Resistive plate chamber , quality assurance , ATLAS
Journal title
Astroparticle Physics
Record number
2025177