Author/Authors :
Cerati، نويسنده , , G.B. and Dinardo، نويسنده , , M.E. and Florez، نويسنده , , A. and Kwan، نويسنده , , S. and Lopez، نويسنده , , A. and Magni، نويسنده , , S. and Malvezzi، نويسنده , , S. and Menasce، نويسنده , , D. and Moroni، نويسنده , , L. and Newsom، نويسنده , , C.R. and Pedrini، نويسنده , , D. and Rovere، نويسنده , , M. Montserrat Sala، نويسنده , , S. and Tan، نويسنده , , P. and Taroni، نويسنده , , S. and Turqueti، نويسنده , , M. and Uplegger، نويسنده , , L، نويسنده ,
Abstract :
In this paper we present some results on the radiation tolerance of the CMS forward pixel detector. They were obtained from a beam test at Fermilab of a pixel-detector module, which was previously irradiated up to a maximum dose of 45 Mrad of protons at 200 MeV. It is shown that CMS forward pixel detector can tolerate this radiation dose without any major deterioration of its performance.