Title of article :
Fusion neutron detector calibration using a table-top laser generated plasma neutron source
Author/Authors :
Hartke، نويسنده , , R. and Symes، نويسنده , , D.R. and Buersgens، نويسنده , , F. and Ruggles، نويسنده , , L.E. and Porter، نويسنده , , J.L. and Ditmire، نويسنده , , T.، نويسنده ,
Pages :
6
From page :
464
To page :
469
Abstract :
Using a high intensity, femtosecond laser driven neutron source, a high-sensitivity neutron detector was calibrated. This detector is designed for observing fusion neutrons at the Z accelerator in Sandia National Laboratories. Nuclear fusion from laser driven deuterium cluster explosions was used to generate a clean source of nearly monoenergetic 2.45 MeV neutrons at a well-defined time. This source can run at 10 Hz and was used to build up a clean pulse-height spectrum on scintillating neutron detectors giving a very accurate calibration for neutron yields at 2.45 MeV.
Keywords :
Laser , Cluster , Fusion , Calibration , detector , Neutron
Journal title :
Astroparticle Physics
Record number :
2025820
Link To Document :
بازگشت