Title of article
Detection systems for short-time stroboscopic neutron imaging and measurements on a rotating engine
Author/Authors
Schillinger، نويسنده , , B. and Abele، نويسنده , , H. and Brunner، نويسنده , , J. and Frei، نويسنده , , G. and Gنhler، نويسنده , , R. and Gildemeister، نويسنده , , A. and Hillenbach، نويسنده , , A. and Lehmann، نويسنده , , E. and Vontobel، نويسنده , , P.، نويسنده ,
Pages
6
From page
142
To page
147
Abstract
Todayʹs neutron sources do not deliver sufficient flux to examine singular short-time events in the millisecond range by neutron radiography.
r, periodic processes can be examined if a triggered accumulating detector collects information of identical time-windows and positions over several cycles of the process. The same problem applies if the source signal itself carries information, like the energy–time dependence in the pulse of a spallation source.
l possible detection methods were considered; measurements were performed at the intense neutron beam H9 of ILL Grenoble, where an electrically driven BMW engine was examined at 1000 rpm with time resolution of 200 μs.
Keywords
Stroboscopic imaging , Neutron radiography , CCD detector , Neutron scintillator , Photo multiplier , Short-time imaging
Journal title
Astroparticle Physics
Record number
2026001
Link To Document