Title of article :
Radiation shielding of high-energy neutrons in SAD
Author/Authors :
Per Seltborg، نويسنده , , P. and Polanski، نويسنده , , A. and Petrochenkov، نويسنده , , S. and Lopatkin، نويسنده , , A. and Gudowski، نويسنده , , W. and Shvetsov، نويسنده , , V.، نويسنده ,
Abstract :
The radiation fields and the effective dose at the Sub-critical Assembly in Dubna (SAD) have been studied with the Monte Carlo code MCNPX. The effective dose above the shielding, i.e. in the direction of the incident proton beam of 3.0 μA, was found to be about 190 μSv h−1. This value meets the dose limits according to Russian radiation protection regulations, provided that access to the rooms in this area is not allowed for working personnel during operation.
arating the radiation fields into a spallation- and a fission-induced part, it was shown that the neutrons with energy higher than 10 MeV, originating exclusively from the proton-induced spallation reactions in the target, contribute for the entire part of the radiation fields and the effective dose at the top of the shielding. Consequently, the effective dose above the SAD reactor system is merely dependent on the proton beam properties and not on the reactivity of the core.
Keywords :
SAD , MCNPX , effective dose , sub-critical , ADS , High-energy neutrons