Title of article :
Optical configurations for pump and probe experiments with a VUV free-electron laser
Author/Authors :
de Castro، نويسنده , , A.R.B. and Mِller، نويسنده , , T.، نويسنده ,
Pages :
10
From page :
568
To page :
577
Abstract :
We discuss strategies for color separation and recombination, regarding 2-color pump-and-probe experiments planned for the DESY XUV FEL Phase 2. We show that efficient handling of the pump and probe components, with good spectral and spatial separation, is possible with either filters or gratings; the former are cheap while the latter are continuously tunable over a range. patial overlap of the pump and probe on a spot 5×8 μm2 FWHM, limited by surface slope errors on the optics, can be achieved with a Kirkpatrick-Baez pair of cylindrical elliptic mirrors placed about 500 mm away from the sample position. l loading is also discussed. It is found that the filters cannot survive more than a few dozen FEL pulses in a train, while a grating on a water-cooled silicon thin blade will present unacceptable surface slope errors after about 1800 FEL pulses on a train.
Keywords :
Pump-and-probe , thermal load , XUV optics , XUV free-electron-laser
Journal title :
Astroparticle Physics
Record number :
2026775
Link To Document :