Title of article
Precise measurement of first Townsend coefficient, using parallel plate avalanche chamber
Author/Authors
Nakhostin، نويسنده , , Mohammad and Baba، نويسنده , , Mamoru and Ohtsuki، نويسنده , , Tsutomu and Oishi، نويسنده , , Takuji and Itoga، نويسنده , , Toshiro، نويسنده ,
Pages
5
From page
999
To page
1003
Abstract
By employing iso-C4H10 gas, we have studied the effective parameters in the first Townsend coefficient measurement using parallel plate avalanche chamber (PPAC). Obtained results are free from space charge and gap deformation effects, which have seriously affected previous PPAC-based measurements. The required conditions for a reliable Townsend coefficient measurement are presented as well.
Keywords
First Townsend coefficient , Parallel plate avalanche chamber , Iso-C4H10
Journal title
Astroparticle Physics
Record number
2027932