Title of article :
Flux calculations for the upgrade of the SANS facility at the Petten-reactor
Author/Authors :
Uca، نويسنده , , O. and Ohms، نويسنده , , C. and Youtsos، نويسنده , , A.G.، نويسنده ,
Pages :
6
From page :
367
To page :
372
Abstract :
The absolute flux at the sample position of the Small-Angle Neutron Scattering instrument is an important parameter in instrument construction. In this paper, analytical expressions are obtained to calculate the flux at the sample position. The used approach has been validated on different instruments. An increase of the flux with two orders of magnitude is foreseen after completion of the upgrade.
Keywords :
neutron flux , Velocity selector , Neutron guide , Pyrolytic graphite , Collimator
Journal title :
Astroparticle Physics
Record number :
2027986
Link To Document :