Author/Authors :
Natkaniec، نويسنده , , Z. and Aihara، نويسنده , , H. and Asano، نويسنده , , Y. and Aso، نويسنده , , T. and Bakich، نويسنده , , A. and Browder، نويسنده , , T. and Chang، نويسنده , , M.C. and Chao، نويسنده , , Y. and Chen، نويسنده , , K.F. and Chidzik، نويسنده , , S. and Chouvikov، نويسنده , , A. and Dalseno، نويسنده , , J. and Dowd، نويسنده , , R. and Fernholz، نويسنده , , R. and Fratina، نويسنده , , Kurt S. and Friedl، نويسنده , , M. and Fujii، نويسنده , , H. ، نويسنده ,
Abstract :
The old silicon vertex detector (SVD1) of the Belle detector, operating at the high-luminosity asymmetric energy e+e− collider KEKB, was replaced by an upgraded version (SVD2) in 2003. The new detector has modified geometry and redesigned readout electronics, providing a larger polar angle acceptance, better vertex resolution, improved radiation hardness and reduced dead time. The operation of the detector started successfully in October 2003. The basic concepts of the SVD2 design as well as its performance after 10 months of data taking are described in this paper.
Keywords :
KEKB , Belle , Silicon detector , Silicon strip detector , SVD