Author/Authors :
Gasparyan، نويسنده , , P.D. and Gusikhina، نويسنده , , I.A. and Lobanova، نويسنده , , Yu.L. and Zhidkov، نويسنده , , N.V. and Subbotin، نويسنده , , A.N. and Tsoi، نويسنده , , E.S.، نويسنده ,
Abstract :
The paper describes the results of measurements carried out at VNIIEF on a laser facility ISKRA-5 with spherical targets of different type. Spectra of X-rays are measured with the aid of cylindrical Ni/C multilayer mirror (MM). To absolutely normalize the results of spectral measurements, there is additionally registered X-rays by semiconductor detectors with different filters. Detectors’ serviceability at operation in the mode of deep current saturation is demonstrated. Experimental and calculation data of spectrum of target X-rays are presented and compared.