Title of article :
First tests of thick GEMs with electrodes made of a resistive kapton
Author/Authors :
Oliveira، نويسنده , , R. and Peskov، نويسنده , , V. and Pietropaolo، نويسنده , , F. and Picchi، نويسنده , , P.، نويسنده ,
Abstract :
We have developed a new design of a GEM-like detector with electrodes made of a resistive kapton. This detector can operate at gains close to 10 5 even in pure noble gases (Ar and Ne) and if transited to discharges at higher gains, due to the high resistivity of electrodes, they do not damage either the detector or the front-end electronics. Gains ∼ 10 6 can be achieved in a cascaded mode of operation. The detector can operate without gain degradation at counting rates of at least up to 10 4 Hz / cm 2 and it could thus be very useful in many applications requiring safe high-gain operation, for example, in RICH, TPCs, and calorimetry.
Keywords :
Micropattern gaseous detectors , GEM , Raether limit
Journal title :
Astroparticle Physics