• Title of article

    Calculation of activation and dose spatial distributions induced by high intensity uranium beams at the Super-FRS fragment separator at FAIR

  • Author/Authors

    Iwase ، نويسنده , , Hiroshi and Weick، نويسنده , , Helmut and Radon، نويسنده , , Torsten and Gutermuth، نويسنده , , Frank and Winkler، نويسنده , , Martin and Geissel، نويسنده , , Hans، نويسنده ,

  • Pages
    4
  • From page
    972
  • To page
    975
  • Abstract
    A model for the calculation of activation induced dose spatial distribution caused by heavy ion irradiation was developed for the design of the shielding and operation of the Super-FRS, which is under development for the future project at FAIR GSI. The model is divided into; (1) Residual nuclei calculation using the heavy ion Monte Carlo code PHITS, (2) activation calculation, (3) dose conversion, and (4) dose attenuation calculation. The model was prepared rather simple, however it showed good agreement with measured data on a benchmark calculation.
  • Keywords
    heavy ion , RADIOACTIVITY , Transport code , PHITS , dose
  • Journal title
    Astroparticle Physics
  • Record number

    2028940