Title of article
Fine synchronization of the CMS muon drift tubes local trigger
Author/Authors
Aldaya، نويسنده , , M. and Amapane، نويسنده , , N. and Battilana، نويسنده , , C. and Bellato، نويسنده , , M. and Benvenuti، نويسنده , , A. and Bonacorsi، نويسنده , , D. and Bontenackels، نويسنده , , M. and Capiluppi، نويسنده , , P. and Castellani، نويسنده , , L. and Cavallo، نويسنده , , F.R. and Cerminara، نويسنده , , G. and Cerrada، نويسنده , , M. and Checchia، نويسنده , , P. and Conti، نويسنده , , E. and de la Cruz، نويسنده , , B، نويسنده ,
Pages
9
From page
169
To page
177
Abstract
The drift tubes based CMS barrel muon trigger, which uses self-triggering arrays of drift tubes, is able to perform the identification of the muon parent bunch crossing using a rather sophisticated algorithm. The identification is unique only if the trigger chain is correctly synchronized. Some beam test time was devoted to take data useful to investigate the synchronization of the trigger electronics with the machine clock. Possible alternatives were verified and the dependence on muon track properties was studied.
Keywords
LHC , CMS , Muon detectors , Muon trigger
Journal title
Astroparticle Physics
Record number
2029173
Link To Document