Title of article
Passive neutron detection for interdiction of nuclear material at borders
Author/Authors
Kouzes، نويسنده , , Richard T. and Siciliano، نويسنده , , Edward R. and Ely، نويسنده , , James H. and Keller، نويسنده , , Paul E. and McConn، نويسنده , , Ronald J.، نويسنده ,
Pages
18
From page
383
To page
400
Abstract
Radiation portal monitor systems based upon polyvinyl toluene scintillator gamma-ray detectors and pressurized 3He-based neutron detector tubes have been deployed to detect illicit trafficking in radioactive materials at international border crossings. This paper reviews the neutron detection requirements and capabilities of passive, as opposed to active interrogation, detection systems used for screening of high-volume commerce for illicit sources of radiation at international border crossings. Computational results are given for the impact of cargo materials on neutron spectra, for the response of various detector geometries, the effects of backgrounds including “ship effect” neutrons, and for simulation of a large neutron detection array.
Keywords
homeland security , Border security , Monte Carlo modeling , Detection of illicit materials , Portal monitor , Ship effect , neutron detection , Radiation detection
Journal title
Astroparticle Physics
Record number
2031418