• Title of article

    Radiation detector based on piezoelectric lead zirconate titanate material

  • Author/Authors

    Takechi، نويسنده , , Seiji and Miyachi، نويسنده , , Takashi and Fujii، نويسنده , , Masayuki and Hasebe، نويسنده , , Nobuyuki and Mori، نويسنده , , Kunishiro and Shibata، نويسنده , , Hiromi and Murakami، نويسنده , , Takeshi and Uchihori، نويسنده , , Yukio and Okada، نويسنده , , Nagaya، نويسنده ,

  • Pages
    5
  • From page
    309
  • To page
    313
  • Abstract
    The feasibility of using piezoelectric lead zirconate titanate (PZT) elements as a radiation detector was examined. We tried to observe the pressure wave excited by irradiating liquid ethanol (C2H5OH) with a 400 MeV/n xenon (Xe) beam using an array of PZT elements, while changing the position of beam irradiation. The elements were designed to obtain two independent electric signals in order to estimate the beam position in one direction on a two-dimensional plane. The time at which the peak of the output signal appeared differed between the two signals obtained from one element under limited experimental conditions. This suggests that the trajectory of the Xe beam may be determined in three-dimensional space with an improved array of the PZT elements.
  • Keywords
    Acoustic radiation detector , Piezoelectricity , PZT element , Radiology
  • Journal title
    Astroparticle Physics
  • Record number

    2031504