Title of article
Testing of photomultiplier tubes for use in the surface detector of the Pierre Auger observatory
Author/Authors
Barnhill، نويسنده , , D. and Suarez، نويسنده , , F. and Arisaka، نويسنده , , K. and Garcia، نويسنده , , B. and Gongora، نويسنده , , J.P. and Lucero، نويسنده , , A. and Navarro، نويسنده , , I. and Ohnuki، نويسنده , , T. and Risi، نويسنده , , A. and Tripathi، نويسنده , , A.، نويسنده ,
Pages
14
From page
453
To page
466
Abstract
In the array of water Cherenkov detectors of the Pierre Auger Observatory, 4800 large photomultiplier tubes (PMTs) will be used. Before being deployed, each PMT is evaluated to check that various parameters, such as the linearity, dark noise, and gain, fall within a specified range. The large scale test system, designed and constructed for this purpose, is capable of testing multiple large PMTs simultaneously. The test system and the results of the tests for the first 3964 PMTs are presented in this paper.
Keywords
Pierre Auger , Astroparticle physics , Water cherenkov , Photodetectors , Cosmic rays , PMTs