    Mosayebi Saman، Mohsen نويسنده 1 Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, 2Medical Image and Signal Processing Research Center, Isfahan University of Medical Sciences,Isfahan,Iran , , Mahnam، Amin نويسنده Department of Biomedical Engineering, School of Engineering, University of Isfahan, Isfahan, Iran , , Hosseini، Nasrin نويسنده Department of Physiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan ,

  • Issue Information
    فصلنامه با شماره پیاپی سال 2014
  • Pages
    9
  • From page
    94
  • To page
    102
  • Abstract
    Portable wireless neuro stimulators have been developed to facilitate long term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 µA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 µA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long term experiments in the field of cognitive and neuroscience research.
  • Journal title
    Journal of Medical Signals and Sensors (JMSS)
  • Serial Year
    2014
  • Journal title
    Journal of Medical Signals and Sensors (JMSS)
  • Record number

    2050167