Author/Authors :
Xu، نويسنده , , Zong Wei and Liang، نويسنده , , Ying-Chun and Dong، نويسنده , , Shen and Cao، نويسنده , , Yong-Zhi and Zhao، نويسنده , , Tie Qiang and Wang، نويسنده , , Jing He and Zhao، نويسنده , , Qing Liang، نويسنده ,
Abstract :
The effects of free amplitude and amplitude setpoint on phase contrast images of poly (styrene–ethylene/butylenes–styrene) (SEBS) triblock copolymer have been studied by carbon nanotubes probe (CNTs probe). Phase angle contrast arises from different energy dissipation that occurs as a result of tip–sample adhesion and sampleʹs viscoelasticity. With increasing free amplitude, phase angle contrast is a stronger function of the sampleʹs viscoelasticity. However, the effect of tip–sample adhesion on phase angle contrast will increase with decreasing free amplitude or amplitude setpoint. The amplitude versus tip–sample distance curve shows both a local maximum and a local minimum that are caused by attractive and repulsive tip–sample interactions at low free amplitude. When amplitude setpoint is in the range between the local maximum and the local minimum value, the phase contrast image would likely produce severe instabilities. In addition, an interesting difference is found in the force plot curve on SEBS sample by using CNTs probe and ordinary silicon probe.