Title of article :
Stress induced domain switching of PZT in compression tests
Author/Authors :
Calderon-Moreno، نويسنده , , Jose M، نويسنده ,
Pages :
4
From page :
227
To page :
230
Abstract :
The stress–strain behavior of soft and hard lead zirconate titanate (PZT) materials has been determined in compression tests. Compressive stress–strain curves are used for the prediction of internal stresses caused by domain switching in piezoelectric actuators. The calculated domain switching versus internal stresses is presented for the different materials and results discussed. Prediction of irreversible domain switching behavior during operation and during poling procedure will help to prevent associated fatigue effects and structural damage.
Keywords :
Stress-strain behavior in compression tests , Stress induced domain switching , Soft and hard PZT
Journal title :
Astroparticle Physics
Record number :
2059208
Link To Document :
بازگشت