Title of article
The creation of pollution mapping and measurement of ambient concentration of sulfur dioxide and nitrogen dioxide with passive sampler
Author/Authors
Akdemir، Andaç نويسنده Engineering Faculty, Department of Environmental Engineering, Ondokuz May?s University, 55200 Samsun, Turkey ,
Issue Information
ماهنامه با شماره پیاپی 0 سال 2014
Pages
9
From page
1
To page
9
Abstract
Background: Measurements of nitrogen and sulfur dioxide using passive sampler over 12 months in Samsun,
Turkey, are compared with SO2 and NO2 concentrations obtained from a co-located chemiluminescence analyzer.
The concentrations of Sulfur and nitrogen dioxide in the ambient air during the period from November 2009 to
September 2010 are analyzed.
Results: The highest value for annual NO2 and SO2 averages of passive sampler was 29.65 ?g/m3 and 21.01 ?g/m3
for exposures of 2-weeks at an industrial site. The maximum monthly concentration for SO2 was observed at
the 10th measurement station with 44.19 ?g/m3 for August. The maximum monthly concentration for NO2 was
observed on the 3rd measurement station with 42.83 ?g/m3 for November. A negative correlation between nitrogen
dioxide concentrations and temperature (R2 = ?0.5489) was estimated. A positive correlation between nitrogen
dioxide measurement with passive sampler and continuous measurement (R2 = 0.6571) was estimated.