Title of article
The use of modified electrodes by hybrid systems gold nanoparticles/Mn-porphyrin in electrochemical detection of cysteine
Author/Authors
Gallo، نويسنده , , Mariana C. and Pires، نويسنده , , Bruno M. and Toledo، نويسنده , , Kalil C.F. and Jannuzzi، نويسنده , , Sergio A.V. and Arruda، نويسنده , , Eduardo G.R. and Formiga، نويسنده , , André L.B. and Bonacin، نويسنده , , Juliano A.، نويسنده ,
Issue Information
دوماهنامه با شماره پیاپی سال 2014
Pages
5
From page
335
To page
339
Abstract
Monitoring of biomarkers can be used to early diagnosis of diseases. Changes in levels of cysteine can indicate several disorders, because of this, development of suitable sensors are essential to welfare of people. Herein it was described the electrochemical response of a hybrid system modified electrode composed by gold nanoparticles and manganese meso-tetra(pentafluorophenyl) porphyrin for the sensing of cysteine. For this purpose, fluorine tin oxide-coated glass (FTO) electrodes were chosen as substrate due to their low cost and easily modifying surface. The hybrid system was deposited on the FTO surface using a self-assembly strategy and all experiments were performed at pH 7.0. The obtained modified electrode has shown good response for cysteine oxidation in amperometric studies with figures of merit comparable to other sensors described in literature.
Keywords
FTO electrodes , Mn porphyrin , Gold nanoparticles , Sensors , Cysteine
Journal title
Synthetic Metals
Serial Year
2014
Journal title
Synthetic Metals
Record number
2091952
Link To Document