Title of article
Development of high Zr-containing Ti-based alloys with low Youngʹs modulus for use in removable implants
Author/Authors
Zhao، نويسنده , , Xiaoli and Niinomi، نويسنده , , Mitsuo and Nakai، نويسنده , , Masaaki and Ishimoto، نويسنده , , Takuya and Nakano، نويسنده , , Takayoshi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
9
From page
1436
To page
1444
Abstract
This research focuses on the development of new titanium (Ti) alloys with a low Youngʹs modulus for use in removable implants. In this study, Ti-30Zr alloy was selected as the base alloy, and the effect of Mo addition on the microstructures, Youngʹs moduli, and tensile properties of Ti-30Zr-(0–8 wt.% Mo) alloys was investigated in this study to assess the mechanical compatibility of these alloys for biomedical applications. Further, the cytocompatibility of a part of the designed alloys was examined. The experimental results indicate that both the microstructures and the mechanical properties of the designed alloys are strongly affected by the Mo contents. The Ti-30Zr-(6, 7 wt.%) Mo alloys, located near the boundary of (β + ω)/β with a metastable structure, show a good combination of a low Youngʹs modulus, high tensile strength, fairly large elongation. In addition, Ti–30Zr–7Mo alloy is highly cytocompatible.
Keywords
High Zr-containing Ti alloys , Mechanical Property , microstructure , Cell culture test