Title of article :
Determination of Carboxylic Acids in Apple Juice by RP HPLC
Author/Authors :
-، - نويسنده Department of Chemistry, Art & Science Faculty, Suleyman Demirel University, 32260 Isparta, TURKEY Akta?, A. Hakan , -، - نويسنده Department of Chemistry, Art & Science Faculty, Suleyman Demirel University, 32260 Isparta, TURKEY ?en, Songül , -، - نويسنده Department of Chemistry, Art & Science Faculty, Suleyman Demirel University, 32260 Isparta, TURKEY Y?lmazer, Mustafa , -، - نويسنده Department of Chemistry, Art & Science Faculty, Suleyman Demirel University, 32260 Isparta, TURKEY Cubuk, Ebru
Issue Information :
فصلنامه با شماره پیاپی 33 سال 2005
Pages :
6
From page :
1
To page :
6
Abstract :
-
Abstract :
Low molecular weight organic acids are most predominant in apple juice among these components fumaric acid was not exceed more than 5 ppm. It was thought that the HPLC is the best method of the determination of organic acids in the apple juice. In this study, chromatographic separation of organic acids of apple juice was obtained by preparing a sample and by applying them to acid phase for extraction and various organic acids content of apple juice, fumaric acid, oxalic acid, tartaric acid and shikimic acids were commented as qualitative and quantitative, too.The organic acids, of which the chromatographic separations were examined, were the acids of fumaric acid, oxalic acid, tartaric acid, ascorbic acid, lactic acid, malic acid, succinic acid and shikimic acid. For this separation, the suitable value are determined by regulating the pH of mobile phase with phosphoric acid in range of pKa ±1.5 (This is the space in which the capacity factors are effectively changed). The concentration of juice was distilled to 11.2 Brix and same pH was applied to cartridge by adjusting with the phosphate buffer at 8.00, and the cartridge was washed with the same buffer and the phase was combined with the first eluant. A suitable distilled percentage of samples were injected and injection volume were determined. In this study, the cartridges of Supelco C18 and Waters C18 were used, datas obtained by both types of cartridges were compared. In this study, the methods of external calibration and added method of standards were applied and slopes were compared.
Journal title :
Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
Serial Year :
2005
Journal title :
Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
Record number :
2124756
Link To Document :
بازگشت