Title of article :
An in vitro evaluation of microtensile bond strengths of two adhesive bonding agents to residual dentine after caries removal using three excavation techniques
Author/Authors :
Banerjee، نويسنده , , A. and Kellow، نويسنده , , S. and Mannocci، نويسنده , , F. and Cook، نويسنده , , R.J. and Watson، نويسنده , , T.F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
10
From page :
480
To page :
489
Abstract :
Objectives ess amounts of residual dentine retained after using three excavation techniques; the microtensile bond strengths (μTBS) to residual dentine, comparing etch-rinse vs. self-etching adhesives. s ious molars were subdivided (N = 21) dependent upon adhesive/composite system (Adper Scotchbond 1XT and Filtek Supreme vs. Filtek Silorane adhesive and composite). Dividing into three (N = 7), dependent upon caries excavation technique employed (hand vs. chemo-mechanical: Carisolv™ gel vs. experimental enzymatic gel (SFC-V)), caries removal was assessed using visual/tactile criteria and in situ autofluorescence (AF) confocal fibre-optic micro-endoscopy (CFOME). Post-restoration/four-week hydrated storage, four 0.9 mm2 beams per tooth underwent μTBS testing/microscopic analysis of fractured surfaces. Three cavities from each excavation group were analysed using SEM. s vealed surface roughness with smear layer occluding tubule orifices in hand-excavated samples and a reduced, variable smear layer for both chemo-mechanical systems. CFOME AF assessment indicated hand excavation left sound dentine, Carisolv™ left affected dentine and SFC-V slightly under-prepared clinically. Mean μTBS values from etch-rinse samples (27 MPa (SD 3.9), hand; 22 MPa (SD 5.1), Carisolv™; 26 MPa (SD 4.4), SFC-V) showed statistical differences between hand and Carisolv™ groups. Mean μTBS data for self-etch samples (22 MPa (SD 3.3), hand; 27 MPa (SD 6.1), Carisolv™; 25 MPa (SD 4.7), SFC-V) showed significant differences between hand and Carisolv™, and hand vs. SFC-V. Failure loci distribution in etch-rinse samples was between dentine–adhesive, within adhesive and within composite whereas self-etch samples exhibited failure predominantly between adhesive and composite. sions ndicated that all null hypotheses were disproved.
Keywords :
Dentine , Caries , excavation , Microtensile bond strength , Dentine bonding agent , confocal microscopy , Composite , Carisolv™ gel , Silorane , Biosolv
Journal title :
Journal of Dentistry
Serial Year :
2010
Journal title :
Journal of Dentistry
Record number :
2129172
Link To Document :
بازگشت