Title of article :
Marginal quality of posterior microhybrid resin composite restorations applied using two polymerisation protocols: 5-year randomised split mouth trial
Author/Authors :
Barabanti، نويسنده , , Nicola and Gagliani، نويسنده , , Massimo and Roulet، نويسنده , , Jean-François and Testori، نويسنده , , Tiziano and ضzcan، نويسنده , , Mutlu and Cerutti، نويسنده , , Antonio، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
436
To page :
442
Abstract :
Objectives andomised, split-mouth clinical study evaluated the marginal quality of direct Class I and Class II restorations made of microhybrid composite and applied using two polymerisation protocols, using two margin evaluation criteria. s l of 50 patients (mean age: 33 years) received 100 direct Class I or Class II restorations in premolars or molars. Three calibrated operators made the restorations. After conditioning the tooth with 2-step etch-and-rinse adhesive, restorations were made incrementally using microhybrid composite (Tetric EvoCeram). Each layer was polymerised using a polymerisation device operated either at regular mode (600–650 mW/cm2 for 20 s) (RM) or high-power (1200–1300 mW/cm2 for 10 s) mode (HPM). Two independent calibrated operators evaluated the restorations 1 week after restoration placement (baseline), at 6 months and thereafter annually up to 5 years using modified USPHS and SQUACE criteria. Data were analyzed using Mann–Whitney U-test (α = 0.05). s cores (USPHS) for marginal adaptation (86% and 88% for RM and HPM, respectively) and marginal discoloration (88% and 88%, for RM and HPM, respectively) did not show significant differences between the two-polymerisation protocols (p > 0.05). Alfa scores (SQUACE) for marginal adaptation (88% and 88% for RM and HPM, respectively) and marginal discoloration (94% and 94%, for RM and HPM, respectively) were also not significantly different at 5th year (p >0.05). sion r and high-power polymerisation protocols had no influence on the marginal quality of the microhybrid composite tested up to 5 years. Both modified USPHS and SQUACE criteria confirmed that regardless of the polymerisation mode, marginal quality of the restorations deteriorated compared to baseline.
Keywords :
Clinical study , Composite , RCT , polymerisation , Marginal quality , Class I and II restorations , USPHS , SQUACE
Journal title :
Journal of Dentistry
Serial Year :
2013
Journal title :
Journal of Dentistry
Record number :
2129942
Link To Document :
بازگشت