• Title of article

    Biochemical sensors with structured and porous silicon capacitors

  • Author/Authors

    Lüth، نويسنده , , Hans and Thust، نويسنده , , Marion and Steffen، نويسنده , , Alfred and Kordos، نويسنده , , Peter and Schِning، نويسنده , , Michael J، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    5
  • From page
    104
  • To page
    108
  • Abstract
    Chemical sensors with structured and porous semiconductor/insulator capacitors have been developed. The sensors have been prepared using standard techniques of semiconductor processing, i.e. by means of an anisotropic and anodic etching process, respectively. Both sensor types exhibit a high, near-Nernstian pH sensitivity of about 54 mV per pH decade. Due to the enlargement of the active sensor area, the measured capacitance values increase up to a factor of 30. These structured and porous electrolyte–insulator–semiconductor (EIS) sensor substrates are suitable as transducer material for biosensors which has been demonstrated by depositing the enzyme penicillinase through physical adsorption onto the respective pH-sensitive EIS capacitors.
  • Keywords
    Biochemical sensor , Porous silicon , pH sensor , Penicillin sensor , Structured silicon , EIS capacitor
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: B
  • Serial Year
    2000
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: B
  • Record number

    2134835