Title of article :
Evaluation of Parameters Influencing Hexavalent Chromium Mist Sampling: A Full Factorial Design
Author/Authors :
-، - نويسنده School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN Tirgar, Aram , -، - نويسنده School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN Golbabaei, Farideh , -، - نويسنده School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN Nourijelyani, Keramat , -، - نويسنده Medical University of Ohio at Toledo, P.O. Box 43614 Ohio, U.S.A Akbar Kanzadeh, Farhang , -، - نويسنده School of Public Health, Center for Environmental Research, Medical Sciences / University of Tehran, Tehran, I.R. IRAN Shahtaheri,, Sayed Jamaleddin , -، - نويسنده School of Chemistry, University of Tehran, P.O. Box 14155-8464 Tehran, I.R. IRAN Ganjali, Mohammad Reza , -، - نويسنده School of Chemistry, University of Tehran, P.O. Box 14155-8464 Tehran, I.R. IRAN Hamedi, Javad
Issue Information :
فصلنامه با شماره پیاپی 44 سال 2007
Pages :
7
From page :
115
To page :
121
Abstract :
-
Abstract :
A chromium electroplating bath with the ability to produce homogenous mist was used to evaluate parameters influencing hexavalent chromium (Cr+6) mist sampling methods. The results of 48 Cr+6mist samples collected using the U.S. National Institute for Occupational Safety and Health method 7600showed that Cr+6concentration was higher: (1) For sampling by closed-face filter cassettes than for sampling by open-face filter cassettes (P <0.001); (2) for samples collected at 35 cm above the electroplating solution surface than for samples collected at 50 cm (P <0.001); (3) for sampling duration of 30 minutes than for sampling duration of 180 minutes (P <0.001); and, (4) for samples extracted immediately after sampling than for samples with delayed extraction (24 hours after sampling) (P <0.001). It is concluded that the accuracy of Cr+6 mist sampling in electroplating shops will be enhanced when: (1) closed-face filter cassette is used to prevent liquid splash contamination; (2) the recommended sampling height is 35 cm above the solution surface; (3) the sampling duration is short--approximately 30 minutes; and, (4) the extraction of the Cr+6 sample is performed as soon as the sampling is completed.  
Journal title :
Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
Serial Year :
2007
Journal title :
Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
Record number :
2151868
Link To Document :
بازگشت