Title of article :
Retrieval of crystal defect structures from HREM images by simulated evolution I. Basic technique
Author/Authors :
Mِbus، نويسنده , , G.، نويسنده ,
Issue Information :
دوماهنامه با شماره پیاپی سال 1996
Pages :
12
From page :
205
To page :
216
Abstract :
Image interpretation of crystal defect structures by means of HREM and image simulations is performed using an advanced method of iterative digital image matching. HREM image analysis is treated as a high-dimensional numerical optimization problem. The configuration space is found to be highly multi-modal with local optima in both the sub-spaces for the structures and for the imaging parameters. Steepest descent optimization is therefore not always sufficient. The global optimization algorithm of simulated evolution by Schwefel [Numerical Optimization of Computer Models (Wiley, New York, 1981)] is tested in this first part by simulations on metal-sapphire interfaces. The capability of arriving at the globally optimal crystal structure within reasonable error bars is studied as a function of four basic quantities: (i) deviation of the initial structure model from the true solution, (ii) signal-to-noise ratio, (iii) microscope resolution, and (iv) smallest projected bond length. For each of these items a well defined limit exists which, upon crossing, leads to a failure of the technique.
Journal title :
Ultramicroscopy
Serial Year :
1996
Journal title :
Ultramicroscopy
Record number :
2154700
Link To Document :
بازگشت