• Title of article

    Investigation of plastic zones near SCC tips in a pipeline after hydrostatic testing

  • Author/Authors

    Li، نويسنده , , Jian and Elboujdaini، نويسنده , , M. and Gao، نويسنده , , M. and Revie، نويسنده , , R.W.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    7
  • From page
    496
  • To page
    502
  • Abstract
    Stress corrosion cracking (SCC) is an important failure mechanism for oil and gas pipelines. In the past, hydrostatic testing has been frequently used to assess and mitigate stress corrosion cracking. It is commonly agreed that an effective hydrostatic test not only eliminates critical crack-like flaws, but also blunts the sub-critical crack tip thereby suppressing further SCC propagation. However, little study has been done on the plastic deformation that results from the high stress intensity at the crack tip due to hydrostatic testing pressure and its possible role in subsequent SCC propagation. In this study, microstructural details were examined of an API 5L X52 SCC-containing pipe removed from field service. Plastic deformation generated by the hydrostatic testing pressure was revealed by using high-resolution imaging of a focused ion beam (FIB) microscope. The existence of the microscopic plastic zones around some crack tips suggests that caution should be taken when setting up pipeline hydrostatic tests.
  • Keywords
    Pipeline , TEM , SCC , FIB
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Serial Year
    2008
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Record number