Author/Authors :
Bertoni، نويسنده , , G. and Beyers، نويسنده , , E. and Verbeeck، نويسنده , , J. and Mertens، نويسنده , , M. and Cool، نويسنده , , P. and Vansant، نويسنده , , E.F. and Van Tendeloo، نويسنده , , G.، نويسنده ,
Abstract :
We present an efficient method for the quantification of crystalline versus amorphous phase content in mesoporous materials, making use of electron energy loss spectroscopy. The method is based on fitting a superposition of core-loss edges using the maximum likelihood method with measured reference spectra. We apply the method to mesoporous TiO 2 samples. We show that the absolute amount of the crystalline phase can be determined with an accuracy below 5%. This method takes also the amorphous phase into account, where standard X-ray diffraction is only quantitative for crystalline phases and not for amorphous phase.