• Title of article

    Variable magnification dual lens electron holography for semiconductor junction profiling and strain mapping

  • Author/Authors

    Wang، نويسنده , , Florence Y.Y. and Li، نويسنده , , J. and Domenicucci، نويسنده , , A. and Bruley، نويسنده , , J.، نويسنده ,

  • Issue Information
    دوماهنامه با شماره پیاپی سال 2013
  • Pages
    13
  • From page
    117
  • To page
    129
  • Abstract
    Dual lens operation for electron holography, which was developed previously (Wang et al., Ultramicroscopy 101 (2004) 63–72; US patent: 7,015,469 B2 (2006)), is re-investigated for bright field (junction profiling) and dark field (strain mapping) electron holography using FEI instrumentation (i.e. F20 and Titan). It is found that dual lens operation provides a wide operational range for electron holography. In addition, the dark field image tilt increases at high objective lens current to include Si 〈0 0 4〉 diffraction spot. Under the condition of high spatial resolution (1 nm fringe spacing), a large field of view (450 nm), and high fringe contrast (26%) with dual lens operation, a junction map is obtained and strain maps of Si device on 〈2 2 0〉 and 〈0 0 4〉 diffraction are acquired. In this paper, a fringe quality number, N′, which is number of fringe times fringe contrast, is proposed to estimate the quality of an electron hologram and mathematical reasoning for the N′ number is provided.
  • Keywords
    Junction profiling , Strain mapping , Electron holography , Dark field electron holography , Dual lens operation , e-SiGe semiconductor device
  • Journal title
    Ultramicroscopy
  • Serial Year
    2013
  • Journal title
    Ultramicroscopy
  • Record number