Title of article :
The interaction of a nanoscale coherent helium-ion probe with a crystal
Author/Authors :
DʹAlfonso، نويسنده , , A.J. and Forbes، نويسنده , , B.D. and Allen، نويسنده , , L.J.، نويسنده ,
Issue Information :
دوماهنامه با شماره پیاپی سال 2013
Pages :
5
From page :
18
To page :
22
Abstract :
Thickness fringing was recently observed in helium ion microscopy (HIM) when imaging magnesium oxide cubes using a 40 keV convergent probe in scanning transmission mode. Thickness fringing is also observed in electron microscopy and is due to quantum mechanical, coherent, multiple elastic scattering attenuated by inelastic phonon excitation (thermal scattering). A quantum mechanical model for elastic scattering and phonon excitation correctly models the thickness fringes formed by the helium ions. However, unlike the electron case, the signal in the diffraction plane is due mainly to the channeling of ions which have first undergone inelastic thermal scattering in the first few atomic layers so that the origin of the thickness fringes is not due to coherent interference effects. This quantum mechanical model affords insight into the interaction of a nanoscale, focused coherent ion probe with the specimen and allows us to elucidate precisely what is needed to achieve atomic resolution HIM.
Keywords :
Helium Ion Microscopy , Ion scattering theory , Atomic resolution imaging