• Title of article

    On-line micro column preconcentration system based on amino bimodal mesoporous silica nanoparticles as a novel adsorbent for removal and speciation of chromium (III, VI) in environmental samples

  • Author/Authors

    Shirkhanloo، Hamid نويسنده Department of Chemistry, Faculty of Science, K. N. Toosi University of Technology, Tehran, Iran , , Khaligh، Aisan نويسنده Department of Chemistry, Semnan University, Semnan 35131-1911, Iran , , Golbabaei، Farideh نويسنده , , Sadeghi، Zargham نويسنده 1Occupational and Environmental Health Research Center (OEHRC), Iranian Petroleum Industry Health Research Institute (IPIHRI-PIHO), Tehran 1485733111, Ira , , Vahid ، Amir نويسنده Department of Science and Engineering, Faculty of Chemistry, Islamic Azad University, Abhar branch, Abhar, I.R. Iran , , Rashidi، Alimorad نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی 0 سال 2015
  • Pages
    12
  • From page
    1
  • To page
    12
  • Abstract
    Background: Chromium (VI) has toxic and carcinogenic effects. So, determination and speciation of chromium in environmental samples is very important in view of health hazards. In this study, solid phase extraction (SPE) based on bulky amine-functionalized bimodal mesoporous silica nanoparticles (NH2-UVM-7) as a novel nanoadsorbent was applied for preconcentration and speciation of chromium (III, VI) in water samples. Methods: UVM-7 was synthesized via atrane route and subsequently functionalized with amino silane via grafting method. In SPE procedure, polymer tubing as a micro-column was filled with NH2-UVM-7 adsorbent. Preconcentration and speciation of Cr (III) and Cr (VI) ions with NH2-UVM-7 were obtained in water samples due to the fact that only Cr (VI) ions can be complexed with-NH2 groups at optimized pH. Finally, chromium concentration was determined by flame atomic absorption spectrometry (F-AAS). Results: TEM, XRD, and SEM results confirmed the beneficial properties of NH2-UVM-7 as the adsorbent for chromium extraction. Under the optimal conditions, linear calibration curve, detection limit and preconcentration factor were obtained 6–320 ?g/ L, 1.2 ?g/L and 66.7, respectively (RSD < 5 %). The efficiency of nanoadsorbent for preconcentration and extraction of Cr (VI) was 96 %, whereas it was less than 5 % for Cr (III). Conclusions: The developed NH2-UVM7-based SPE/F-AAS method has enough sensitively and simplicity for speciation and determination of Cr (VI) and Cr (III) ions in real water samples. Good recoveries, with low detection limits and good preconcentration factors are the main advantages of this procedure.
  • Journal title
    Iranian Journal of Environmental Health Science and Engineering (IJEHSE)
  • Serial Year
    2015
  • Journal title
    Iranian Journal of Environmental Health Science and Engineering (IJEHSE)
  • Record number

    2159583