• Title of article

    Micromechanisms of damage in a hypereutectic Ti–6Al–4V–B alloy

  • Author/Authors

    Sen، نويسنده , , Indrani and Maheshwari، نويسنده , , L. and Tamirisakandala، نويسنده , , S. and Miracle، نويسنده , , D.B. and Ramamurty، نويسنده , , U.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    5
  • From page
    162
  • To page
    166
  • Abstract
    The tensile stress–strain response and fracture in a hypereutectic Ti–6Al–4V–1.7B (weight percent) alloy were investigated by employing interrupted tensile tests combined with acoustic emission measurements, with the aim to identify the cause for the observed low ductility in this alloy. These tests were complemented with microscopy. The alloy contains TiB whiskers of different length scales, the majority of which include micro-whiskers (∼5–10 μm length) and a few primary-whiskers (∼200–300 μm length). Although the fracture of both types of whiskers occur during deformation, the former leads to a gradual decrease in the secant modulus whereas initiation of the latter leads to a drastic drop in the modulus along with failure of the specimen, limiting the ductility.
  • Keywords
    Titanium alloys , microstructure , Acoustic emission spectroscopy , Interrupted tensile test
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Serial Year
    2009
  • Journal title
    MATERIALS SCIENCE & ENGINEERING: A
  • Record number